Microscope Trinocular YR0231

The Trinocular Laboratory Microscope YR0231 is a top-tier choice for professionals seeking precise imaging. Equipped with a Seidentopf Trinocular Head, this microscope provides a comfortable 30° incline, ensuring ease of use over extended sessions. The backward quintuple nosepiece and Infinity Plan Achromatic Objectives ranging from 4x to 100x deliver exceptional clarity and flexibility, making it ideal for diverse laboratory applications. The advanced halogen lamp and external Kohler Illumination system offer adjustable brightness and consistent lighting conditions, perfect for analyzing specimens with high precision.
This page provides an overview of the Microscope Trinocular YR0231, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in United States, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Microscope Trinocular YR0231, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
Its use is oriented to laboratory routines that require observation, control and operational continuity.
For the market in United States, evaluation should consider local context such as FDA regulation, large hospital networks, biotech hubs and match the product to the real workload of the laboratory.
Market price range

Laboratory microscopes of this caliber typically range from $1,500 to $5,000, depending on additional features and specific configurations. The YR0231 offers excellent value for money, balancing high-performance optics with durability.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In United States, budget comparison should include FDA references, 120V/60Hz power conditions, accessories, logistics and after-sales support.
Value for money

The YR0231 shines with its robust optical system and ergonomic design, ensuring comfort and excellent image quality during extended use. However, its professional-level features and quality might be overwhelming for beginner users.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

To optimize the use of the YR0231 , ensure periodic maintenance and cleaning, especially the lenses and illumination source. Consider equipping the microscope with additional optional accessories for specialized applications, such as dark field or phase contrast kits. For purchasing, request a quotation directly or generate one automatically through Kalstein Plus to take advantage of potential discounts and offers.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to United States helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Microscope Trinocular YR0231

Microscope Trinocular YR0231
- Cabeza trinocular Seidentopf, 30°. Inclinado, giratorio de 360°, interpupilar 48-75 mm, dioptría del tubo del ocular izquierdo ajustable
- Revólver portaobjetivos quíntuple hacia atrás, con ranura deslizante
- Objetivo acromático Infinity Plan 4x, 10x, 40x, 100x
- Platina mecánica de doble capa, 185 x 142 mm, rango de movimiento de 55 x 75 mm
- Condensador basculante NA0.9/0.25
- Lámpara halógena 6V30W, Iluminación externa Kohler, con colector asperical, brillo ajustable FUSIBLE Circuito de protección, reemplazable
- Ajuste coaxial grueso y fino, rango de enfoque de 24 mm, división fina de 0,001 mm, recorrido grueso de 37,7 mm, con bloqueo
Especificaciones técnicas
| Modelo | YR0231 (current) | |
| Sistema óptico | Sistema óptico Infinity Plan | |
| Función | Campo brillante, campo oscuro opcional, polarización, contraste de fase, fluorescente | |
| Cabeza | Cabezal trinocular Seidentopf, inclinado 30°, giratorio 360°, interpupilar 48~75 mm, tubo ocular izquierdo ajustable en dioptrías | |
| Ocular | Ocular de campo extra ancho EW10x/22 mm, tubo ocular de 30 mm de diámetro | |
| Muserola | Revólver portaobjetivos quíntuple hacia atrás, con ranura deslizante | |
| Objetivo | Objetivo acromático Infinity Plan 4x, 10x, 40x, 100x | |
| Enfoque | Ajuste coaxial grueso y fino, rango de enfoque 24 mm, división fina 0,001 mm, recorrido grueso 37,7 mm | |
| Etapa de trabajo | Platina mecánica de doble capa, 185*142 mm, rango de movimiento 55*75 mm | |
| Condensador | Condensador basculante NA0.9/0.25 | |
| Iluminación | Lámpara Halógena 6V30W, Iluminación Kohler Externa, Con Colector Asperical, Brillo Ajustable | |
| Filtrar | Verde azul | |
| Adaptador | Adaptador trinocular + Adaptador de foto de tubo ocular Dia.23.2mm | |
| Accesorios Opcionales | ||
| Cabeza | Cabezal binocular Seidentopf, 30° inclinado, interpupilar 48~75mm | YR0231-op1 |
| Actualización a cabezal binocular inclinable 5°~35° | YR0231-op2 | |
| Actualización a cabezal trinocular basculante 5°~35° | YR0231-op3 | |
| Ocular | Ocular de campo extra ancho EW10x/20 mm, tubo de ocular de 30 mm de diámetro | YR0231-op4 |
| Ocular de campo extra ancho EW20x/12 mm, tubo de ocular de 30 mm de diámetro | YR0231-op5 | |
| Ocular de campo extra ancho EW15x/16 mm, tubo de ocular de 30 mm de diámetro | YR0231-op6 | |
| Objetivo | Objetivo acromático Infinity Plan 20x | YR0231-op7 |
| Objetivo acromático Infinity Plan 60x | YR0231-op8 | |
| Muserola | Revólver séxtuple | YR0231-op9 |
| Iluminación | Actualice a lámpara halógena 24V50W, para una mejor visión en la oscuridad | YR0231-op10 |
| Actualice a la lámpara halógena 24V100W, para una mejor visión en la oscuridad | YR0231-op11 | |
| Adaptador | 0,45x montura C | YR0231-op12 |
| Campo oscuro | Condensador de campo oscuro, NA 0.7~0.9, Seco, | YR0231-op13 |
| Úselo con un objetivo de aumento de 40x o inferior | ||
| Condensador de campo oscuro, NA 1.25~1.36, Inmersión, | YR0231-op14 | |
| Usar con objetivo 100x | ||
| Objetivo de campo oscuro, plan infinito 100x (aceite) | YR0231-op15 | |
| Objetivo de campo oscuro, plan infinito 100x (aceite), con diafragma de iris | YR0231-op16 | |
| Contraste de fase | Conjunto de contraste de fase de torreta Infinity Plan | YR0231-op16 |
| –Condensador de contraste de fase de torreta Infinity Plan | ||
| –Infinity Plan Fase Contraste Objetivo 4x,10x,40x,100x | ||
| –Telescopio de centrado 10x | ||
| –Filtro verde | ||
| Conjunto de contraste de fase de torreta acromática Infinity | YR0231-op17 | |
| –Condensador de contraste de fase de torreta acromática Infinity | ||
| –Objetivo de contraste de fase acromático infinito 4x, 10x, 40x, 100x | ||
| –Telescopio de centrado 10x | ||
| –Filtro verde | ||
| fluorescente | Kit EPI-fluorescente, actualización a A16.1028 | YR0231-op18 |
| –Proveedor de energía 220V/110V Pantalla digital intercambiable | ||
| –100WHBO Lámpara de mercurio esférica de ultra alto voltaje | ||
| –Barrera para resistir la luz ultravioleta | ||
| –Aceite libre de fluorescencia | ||
| –Filtro de excitación B/G | ||
| Kit EPI-fluorescente, actualización a A16.1028 | YR0231-op19 | |
| –Proveedor de energía 220V/110V Pantalla digital intercambiable | ||
| –100WHBO Lámpara de mercurio esférica de ultra alto voltaje | ||
| –Barrera para resistir la luz ultravioleta | ||
| –Aceite libre de fluorescencia | ||
| –Filtro de excitación B/G/V/U | ||
| Kit fluorescente LED EPI, actualización a A16.1029 | YR0231-op20 | |
| Luz EPI 3W LED 465~475nm, filtro de excitación B BP460~490, | ||
| Luz EPI 3W LED 525~530nm, filtro de excitación G BP510~550 | YR0231-op21 | |
| Polarizador | Accesorio polarizador, polarizador, analizador, dispositivo integrado | YR0231-op22 |
Products related to model YR0231

Laboratory Microscope YR06686
Ver producto
Biological Microscope YR06685
Ver producto
LCD Digital Biologcal Microscope YR06684
Ver producto
Biological Microscope YR06685
Ver producto
Laboratory Biological Microscope YR06683
Ver producto
Inverted Biological Phase Contrast Microscope YR06682
Ver producto
Motorized Forensic Comparison Microscope YR06681
Ver producto
Digital Microscope with 10.5″ LCD Touch Screen, 8.0m, Android Pad, Infinity Plan YR06655
Ver productoFrequently Asked Questions about the Microscope Trinocular YR0231
Q: Can the microscope be connected to a camera?
A: Yes, it includes a Trinocular Adapter and a photo adapter, making it easy to connect to imaging devices.
Q: What lighting does it use?
A: It uses a 6V30W adjustable halogen lamp with a Kohler Illumination system.
How do I choose the right microscope trinocular yr0231 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.