Kalstein

Portable Digital Veterinary X-Ray (DR) YR06160

Portable Digital Veterinary X-Ray (DR) YR06160

Pantalla táctil de 10,4 pulgadas Autoprotección contra fallos, autodiagnóstico Control de alta precisión de la tensión y la corriente del tubo 48 tipos de elección del patrón de memoria anatómica presupuesta Método de control de precisión de simulación y doble bucle digital Tubo de rayos X completo de la rendición de plomo para proteger de fugas de rayos X Exposición mediante pantalla táctil, interruptor manual o mando a distancia

This page provides an overview of the Portable Digital Veterinary X-Ray (DR) YR06160, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.

This Kalstein model is available for laboratories in United States, with selection criteria adapted to local purchasing, installation and support conditions.

Ver más

Key factors to consider

Key factors to consider

Before selecting the Portable Digital Veterinary X-Ray (DR) YR06160, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

Its use is oriented to laboratory routines that require observation, control and operational continuity.

For the market in United States, evaluation should consider local context such as FDA regulation, large hospital networks, biotech hubs and match the product to the real workload of the laboratory.

Market price range

Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In United States, budget comparison should include FDA references, 120V/60Hz power conditions, accessories, logistics and after-sales support.

Value for money

Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Advantages and disadvantages

Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Expected lifespan based on use and maintenance

Expected lifespan based on use and maintenance

Model YR06160 Generator Power 5kW kV Range 40~110kV mA Range 20~100 mA mAs Range 0.8-200mAs Working Frequency ≥40kHz Exposure time 40ms~4000ms X-ray tube Anode heat storage 56KHU Focus 1.8 mm Inherent filtration 1mm Al/75Kv Light source LED Wireless flat panel detector Scintillator CSI Active Area 10*13 inches Pixel Matrix 2528*3318 Data Interface WiFi / Tethered Trigger Mode AED (optional) / Software Dimensions 269mm*362mm*16mm Weight 2.2 kg Touch Screen Dimension 10.4 inches Main Unit Weight 19 kg Dimension 290mm*265mm *230mm Power Supply Voltage AC 220V±10%, 50Hz±1Hz

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to United States helps preserve service continuity and plan preventive maintenance without extended downtime.

Specifications table for the Portable Digital Veterinary X-Ray (DR) YR06160

Portable Digital Veterinary X-Ray (DR) YR06160

Portable Digital Veterinary X-Ray (DR) YR06160

Pantalla táctil de 10,4 pulgadas Autoprotección contra fallos, autodiagnóstico Control de alta precisión de la tensión y la corriente del tubo 48 tipos de elección del patrón de memoria anatómica presupuesta Método de control de precisión de simulación y doble bucle digital Tubo de rayos X completo de la rendición de plomo para proteger de fugas de rayos X Exposición mediante pantalla táctil, interruptor manual o mando a distancia
ModelYR06160
Generator
Power5kW
kV Range40~110kV
mA Range20~100 mA
mAs Range0.8-200mAs
Working Frequency≥40kHz
Exposure time40ms~4000ms
X-ray tube
Anode heat storage56KHU
Focus1.8 mm
Inherent filtration1mm Al/75Kv
Light sourceLED
Wireless flat panel detector
ScintillatorCSI
Active Area10*13 inches
Pixel Matrix2528*3318
Data InterfaceWiFi / Tethered
Trigger ModeAED (optional) / Software
Dimensions269mm*362mm*16mm
Weight2.2 kg
Touch ScreenDimension10.4 inches
Main Unit
Weight19 kg
Dimension290mm*265mm *230mm
Power SupplyVoltageAC 220V±10%, 50Hz±1Hz
View product

Frequently Asked Questions about the Portable Digital Veterinary X-Ray (DR) YR06160

How do I choose the right portable digital veterinary x-ray (dr) yr06160 for my laboratory?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?

Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.

Contact Us

Contact Kalstein