Precision Colorimeter YR05509

The Precision Colorimeter YR05509 stands out as a cost-effective solution for measuring color differences in various fields. This innovative device boasts high precision and versatility with its dual aperture feature, accommodating both Φ8mm flat and Φ4mm tip apertures to cater to diverse sample types, especially those with concave surfaces. Equipped with built-in white plate parameters, it eliminates the need for frequent calibrations, offering rapid measurements that are ideal for industries such as plastics, electronics, paints, textiles, food, and more.
This page provides an overview of the Precision Colorimeter YR05509, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in United States, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Precision Colorimeter YR05509, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
In practical scenarios, the Precision Colorimeter YR05509 demonstrates its strength in quality control processes where detecting slight color variations is crucial. Laboratories and manufacturing plants utilize it to ensure color uniformity in products, while research institutes rely on its data for developing new materials.
For the market in United States, evaluation should consider local context such as FDA regulation, large hospital networks, biotech hubs and match the product to the real workload of the laboratory.
Market price range

In the competitive landscape of colorimeters, prices can vary significantly depending on features and accuracy. The Precision Colorimeter YR05509 typically falls within the range of $1600 to $2500 on the market. This makes it a well-valued option considering its precision and functionality. For an exact quote tailored to your specific needs, take advantage of the Kalstein Plus platform's automated quotation tools.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In United States, budget comparison should include FDA references, 120V/60Hz power conditions, accessories, logistics and after-sales support.
Value for money

The YR05509 offers numerous advantages, including its high accuracy, dual aperture capability, and built-in calibration. Its rechargeable battery provides convenience and sustainability. However, for professionals requiring extreme precision beyond ΔE*ab 0.03, alternate high-end models might be needed. Given its features, the device's size may require some adjustment in storage or transit arrangements.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

In practical scenarios, the Precision Colorimeter YR05509 demonstrates its strength in quality control processes where detecting slight color variations is crucial. Laboratories and manufacturing plants utilize it to ensure color uniformity in products, while research institutes rely on its data for developing new materials.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

For optimum performance, users should ensure the device is clean and protected from extreme environmental conditions. Regularly updating the associated software and storing the device in a safe, temperature-controlled environment will extend its lifespan and maintain accuracy.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to United States helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Precision Colorimeter YR05509

Precision Colorimeter YR05509
Ventajas del Producto
- Parámetros de placa blanca incorporados. No es necesario calibrar cada vez que realiza una medición rápida.
- Aperturas dobles: apertura plana de Φ8 mm y apertura de punta de Φ4 mm para interruptor, muestra cóncava fácil de medir en un plano grande.
- Equipado con una batería recargable de iones de litio de alta capacidad incorporada. No es necesario comprar la batería repetidamente.
- Diseño de mano: pequeño y conveniente; facilitar la medición.
- Aspecto exquisito: adopta diseños estéticos tradicionales y de moda.
- Rendimiento de alto costo: gran producción, buena calidad, productos baratos.
Especificaciones Técnicas
| Model | YR05509 (current) |
| Illumination/Geometry Visualization: | 8°/ day |
| Light Source: | LED Light |
| Sensor: | silicon photodiode array |
| Measurement Aperture: | Flat aperture of Φ8 mm; Tip aperture of Φ4 mm |
| Color Space: | CI EL AB, XYZ, LCh, CI E RGB, CI E LUV |
| Color Difference Formula: | ΔE* ab, ΔE(h), ΔE* uv, ΔE* 94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE* 00 |
| Other Chromaticity Data: | WI (E313, CI E, AATCC, Hunter), YI (D1925, 313), Color Fastness, Color Fastness, Staining Fastness, J PC79, BFD(1.5:1), FMCI I |
| Observer: | CI E 10° |
| Illuminant: | D65, A, C, D50, F2, F6, F7, F8, F10, F11, F12 |
| Display Data: | Colorimetric value, color difference value/chart, PASS/FAIL result, color compensation, |
| Measuring Time: | 0.4s |
| Repeatability: | ΔE* ab 0.03 (average of 30 measurements of standard white plate in 5s) |
| Errors Between Instruments: | within Delta E*ab 0.2 |
| Dimension: | 205*67*80mm |
| Weight: | 500g |
| Battery: | rechargeable lithium-ion battery 3.7V @ 3200mAh |
| Lamp Life: | 5 years, over 1.6 million measurements |
| Display: | 2.8 inch TFT (16:9) |
| Interface: | USB/ RS-232 |
| Storage: | 100 standards, 20000 samples |
| Operating Temperature: | 0~40 ℃ (32~104 °F) |
| Storage Temperature: | -20~50 ℃ (-4~122 °F) |
| Computer Software: | CQCS3 Software |
| Optional Accessory: | mini thermal printer, powder testing box |
Products related to model YR05509

High cost-effective portable colorimeter YR05514
Ver producto
High cost-effective Portable Colorimeter YR05515
Ver producto
Spectrocolorimeter YR05516 - YR05517
Ver producto
Spectrocolorimeter YR05518 - YR05519
Ver producto
Precision Colorimeter YR05506 // YR05508
Ver producto
Precision Colorimeter YR05510
Ver producto
Precision Colorimeter YR05511
Ver producto
Precision Colorimeter YR05512
Ver productoFrequently Asked Questions about the Precision Colorimeter YR05509
What industries benefit most from this colorimeter?
The YR05509 is extensively used in plastic, electronic, paint, ink, textile, garment, printing, dyeing, food, medical, and cosmetic industries, among others.
How often do I need to calibrate the device?
Thanks to its built-in white plate parameters, frequent calibration is not necessary, enhancing efficiency.
Is the device portable?
Yes, the handheld design ensures it is lightweight and easy to transport for fieldwork.
How do I choose the right precision colorimeter yr05509 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.