    The YR06922-YR06923 Pure Water Treatment Machine for Dialysis is an advanced solution designed to provide high-quality, ultrapure water, ideal for critical medical applications such as dialysis. With capacities of 500 L/h for the YR06923 model and 1000 L/h for the YR06922 model, this machine ensures efficient and reliable water treatment, essential for guaranteeing patient safety during dialysis procedures. Both models feature a dual-stage pretreatment and treatment system, with a desalination rate of 99.80% and a bacteria and endotoxin removal rate exceeding 99.80%. These systems ensure that the supplied water is of the highest quality, meeting the stringent requirements for dialysis patient treatment.

    Design and Technology

    Both models of the YR06922 and YR06923 Pure Water Treatment Machine incorporate cutting-edge technology to ensure maximum efficiency. They are equipped with a two-stage reverse osmosis (RO) system , enabling effective impurity removal and precise water quality control. Furthermore, their design includes a quartz sand filter , an activated carbon filter , and a water softener —key elements that contribute to continuous water purification. The machine also features a 10″ touchscreen for easy operation and real-time monitoring, as well as PLC electrical control to ensure automatic and uninterrupted operation. The alarm function allows for early detection of any anomalies, guaranteeing a safe and trouble-free water treatment process.

    Frequently Asked Questions

    What is the water treatment capacity of the machine? The machine is available in two versions: 500L/H (YR06923) and 1000L/H (YR06922), allowing you to select the model according to the water volume needs of the installation. What type of maintenance is required? It is important to perform regular maintenance on the reverse osmosis filters and membranes to maintain optimal system performance. It is recommended to check the valves, pressure gauge, and alarm system regularly to ensure treatment effectiveness. Is it compatible with other dialysis machines? Yes, these water treatment systems are compatible with most dialysis machines on the market, provided they meet the necessary ultrapure water requirements.

    Advantages and Disadvantages

    Advantages:
    • High purification efficiency: With a desalination rate of 99.80% and a removal of bacteria and endotoxins greater than 99.80%, the machine guarantees the highest quality water for dialysis.
    • Robust design and easy maintenance: Its robust construction in materials such as FRP and its automatic alarm system facilitate maintenance and ensure continuous and safe operation.
    • Advanced pretreatment technology: Includes an efficient pretreatment system, with quartz sand filters , activated carbon and water softener , ensuring purified water before the reverse osmosis process.
    Disadvantages:
    • High initial cost: Although the machine offers superior performance, the acquisition cost may be a barrier for some healthcare institutions, especially those with tight budgets.
    • It requires space: Its size and capacity require proper installation in dialysis facilities, which can pose a challenge in confined spaces.

    Product Use in the Field

    In real-world settings, the YR06922-YR06923 Pure Water Treatment Machine is primarily used in clinics and hospitals providing dialysis treatments to patients with kidney failure. The system ensures that the water used during dialysis is completely free of impurities, guaranteeing patient safety and well-being. This machine can also be used in laboratories and research centers that require ultrapure water for their procedures and experiments.

    Recommendations

    To maximize the performance and lifespan of the YR06922-YR06923 Pure Water Treatment Machine , it is recommended to:
    • Regular maintenance: Perform periodic checks of the filters, reverse osmosis membranes, and valves. Ensure all components are free of obstructions or damage.
    • Continuous monitoring: Use the touchscreen to constantly monitor the system and make adjustments as needed, especially during peak demand.
    Staff training: Ensure that operating personnel are trained in the proper handling of the system, to guarantee efficient and safe use of the machine.

    Technical Specifications

    Model YR06922 YR06923
    Water Capacity 1000L/H 500L/H
    Nominal Voltage AC 380V/400V/415V/240V, 50/60Hz; 3-phase 4 wires
    Desalination Rate 99.80%
    Recovery Rate 65%-85%
    Ion Removal Rate 99.50%
    Bacteria and Endotoxin Elimination Rate 99.80%
    Operating Temperature 5-40°C
    Technology Adopted Pretreatment system + System (double pass)
    TDS Inlet Water <200PPM
    Quartz Sand Filter Tank 1665(Φ400*1650mm); FRP Tank 1354(Φ330*1350mm); FRP
    Quartz Sand Diameter 4-6 mesh, 75kg Diameter 1-32 mesh, 100kg
    Manganese Sand 50kg
    Control valve F67C1, automatic (Runxin) F67C1, automatic (Runxin)
    Pressure gauge Y60, 0-0.6MPa Y60, 0-0.6MPa
    Activated Carbon Filter Tank 1665(Φ400*1650mm); FRP Tank 1354(Φ330*1350mm); FRP
    Activated carbon 50kg 25kg
    Control valve F67C1, automatic (Runxin) F67C1, automatic (Runxin)
    Pressure gauge Y60, 0-0.6MPa Y60, 0-0.6MPa
    Water Softener Tank 1665(Φ400*1650mm); FRP Tank 1354(Φ330*1350mm); FRP
    Resin 001×7 140kg 80kg
    Precision Filter 8T/H, 316L 5μm, 316L
    High Pressure Pump 1st Stage (CNP) Q=5.0m3/h, H=1.5Mpa, P=4.0KW Q=1.6m3/h, H=1.5Mpa, P=2.2KW
    RO System 1st Step Q=5.0 m3/h, recovery: 70% Q=1.6 m3/h, recovery: 65%
    RO Membrane 1st Step BW30-400IG (8040), LELC-4040 BW30-400IG (8040)
    RO Membrane Housing 1st Step HX-8040 316L, HX-4040 316L HX-8040 316L
    Permeated Water Flow Meter 1st Step 0-8m3/h 0-4m3/h
    Concentrated Water Flow Meter 1st Step 0-4m3/h 0-4m3/h
    RO System 2nd Step Q=2.8m3/h, recovery: 100% Q=1.1m3/h, recovery: 100%
    RO Membranes 2nd Step BW30-400IG (8040) LELC-4040
    RO Membrane Housing 2nd Step HX-8040 316L HX-4040 316L
    Electrical Control PLC + 10″ Touchscreen
    Electrical Control Material Carbon steel
    Alarm function Yeah

    Send us a direct message

    We're here to help you

    Frequently asked questions

    Want to know the air shipping cost to your facility?

    Place your address in the payment section and you'll automatically see the shipping to your door.

    I'm an institution; I need the price for multiple units

    Request a personalized quote in the contact section once you identify the model.

    More answers