Bedside Monitor YR02173

Manufacturer: Kalstein

Manufacturer: Kalstein

Product Description

12.1 inch high resolution LCD display; 35 million clicking times long life touch screen with Accutouch technology; Maximum 168 hours graphic and tabular trends of all parameters; Adjustable respiration lead helps to get accurate RESP reading for different patients; 120mm slim design which is modern and saving place; 112mm removable wide range printer can output 7 waveforms simultaneously.

  • 12.1 inch high resolution LCD display;
  • 35 million clicking times long life touch screen with Accutouch technology;
  • Maximum 168 hours graphic and tabular trends of all parameters;
  • Adjustable respiration lead helps to get accurate RESP reading for different patients;
  • 120mm slim design which is modern and saving place;
  • l112mm removable wide range printer can output 7 waveforms simultaneously.
Model YR02173
ECG
Lead type 3 leads or 5 leads selectable
Input 3-conductor cable: RA; THE; LL or R; L; F
Lead selection
3 leads: I, II, III
Slead: I, Il, Ill, V, AVR, AVL, AVF
ECG waveform 2 channels
To win x0.25, x0.5, x 1, x2, x4, Automatic
Sweep speed 12.Smm / s, 25mm / s, 50mmls
Broadband
Diagnostic mode: 0.05-100Hz
Monitor mode: 0.5-40Hz
Surgical mode: 1.0-25Hz
Defib. Protection
Supports voltage of 5000VAC / 50Hz in isolation
Against electrosurgical interference and defibrillation
ST segment detection
Measurement range: -2.0 mv to 2.0 mv
Alarm range: -2.0 mv to 2.0 mv
Arrhythmia analysis Yes
Rhythm detection Yes
Calculation of drug dose Yes
Standby mode Yes
Heart rate
Distance
Newborn: 15-350 rpm
Adult / pediatric: 15-300 rpm
Precision 1 bpm or 1%, whichever is greater
Resolution 1 bpm
Alarm range
Newborn: 15 ~ 350 rpm
Adult / pediatric: 15-300 rpm
Breathing
Method Thoracic impedance
Measuring range
Newborn / Pediatric: 0-150 rpm
Adult: 0-150 rpm
Apnea alarm Yes, no alarm, 1 Os, 15 s, 20 s, 25 s, 30 s, 35 s, 40 s selectable
Resolution 1 rpm
Sweep speed 6.25mm / s, 12.5mm / s, 25mm / s
NIBP
Method Oscillometric
Modes of operation Manual.Auto.STAT
Parameters Systolic, Middle Diastolic
Systolic pressure range
Adult: 40-270 mmHg
Pediatric: 40-200 mmHg
Newborn: 40-135 mmHg
Diastolic pressure range
Adult: 10-210 mmHg
Pediatric: 10-150 mmHg
Newborn: 10-100 mmHg
Medium pressure range
Adult: 20-230 mmHg
Pediatric: 20-165 mmHg
Newborn: 20-110 mmHg
Precision ± 6 mmHg (± 0.80 kpa)
Resolution 1 mmHg
Overpressure protection Double safety protection

Additional Information

Weight 6 kg
Dimensions 39,5 × 28 × 33 cm
    PARIS – FRANCE

    Company headquarters

    2 rue Jean Lantier, 75001, Paris – France.
    (+33) 1 78 95 87 89(+33) 7 60 83 92 83

    sales.department@kalstein.eu

    LOCATIONS

    We are always close.



    FACILITIES

    Methods of payment and shipping



    Follow our activity on social networks

    Stay informed with all current news of the sector.