Spectrophotometer YR05474

The Pulsed Xenon Lamp Benchtop Spectrophotometer YR05474 is an advanced and precise tool ideal for high-precision color analysis in laboratories and industrial settings. Developed by Kalstein, this cutting-edge spectrophotometer boasts a 7-inch TFT touchscreen for easy navigation and a sophisticated optical geometry suitable for various materials. It efficiently analyzes both opaque and translucent samples with its reflective d/8 and transmissive d/0 (SCI & SCE) optical geometry setup. The key feature of the YR05474 is its pulsed xenon lamp system, paired with a 256-element CMOS sensor, ensuring dependable accuracy and stability across numerous tests.
This page provides an overview of the Table top spectrophotometer with pulsed xenon lamp YR05474, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in United States, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Table top spectrophotometer with pulsed xenon lamp YR05474, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
The versatility of the YR05474 spectrophotometer makes it a valuable asset in product development and quality control laboratories. Ideal for industries such as automotive and cosmetics, it facilitates rigorous analysis by measuring both reflectance and transmittance to uphold stringent quality standards at every production stage.
For the market in United States, evaluation should consider local context such as FDA regulation, large hospital networks, biotech hubs and match the product to the real workload of the laboratory.
Market price range

When comparing high-end spectrophotometers, the YR05474 is priced in the range of $14,200 to $15,000 USD, representing exceptional value for accuracy and durability in advanced color measurement needs. It is competitively placed for industries that rely heavily on precise color calibration, such as automotive, food, medical, and cosmetic sectors. For businesses seeking to streamline their color analysis processes, the Kalstein Plus platform allows for a customized, no-obligation quote to fit specific operational requirements. Get your tailored quote today and capitalize on the advanced features and competitive pricing of the YR05474
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In United States, budget comparison should include FDA references, 120V/60Hz power conditions, accessories, logistics and after-sales support.
Value for money

The YR05474 provides users with several advantages, including a temperature compensation system ensuring accurate results in variable environments, ergonomic design for long-term use, and compatibility with LED and UV light sources. However, the device may require periodic calibration in high-usage scenarios to sustain peak performance.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

The versatility of the YR05474 spectrophotometer makes it a valuable asset in product development and quality control laboratories. Ideal for industries such as automotive and cosmetics, it facilitates rigorous analysis by measuring both reflectance and transmittance to uphold stringent quality standards at every production stage.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

To ensure optimal performance of the YR05474, regular calibrations and maintaining the equipment in a stable environment are highly recommended. Adjusting the measurement aperture according to sample type is vital for precision. Enhance your quality control endeavors by requesting a customized quote through the Kalstein Plus platform, and discover the transformative impact of the YR05474 on your color analysis operations.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to United States helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Spectrophotometer YR05474

Spectrophotometer YR05474
Características
- Alta configuración de hardware: pantalla táctil capacitiva a color TFT de 7 pulgadas; Bluetooth 2.1; Rejilla cóncava.
- Sensor CMOS de doble matriz de 256 elementos de imagen; Lámpara de xenón estable de larga vida útil.
- Con espectro reflectante y transmisivo, valor de laboratorio preciso, bueno para calcular la fórmula de color y hacer una transmisión de color precisa.
- Apertura de medición de identificación automática. Libremente conmutable entre 3 aperturas de medición: Φ 25,4 mm/8 mm/4 mm. Los usuarios también pueden personalizar las aperturas.
- Sensor de temperatura incorporado para monitorear y compensar la temperatura de medición para garantizar una medición más precisa.
- Rango de longitud de onda 360nm - 780nm. Lámpara de xenón de 400nm/420nm/460nm incorporada, más profesional en la medición UV.
- Detector de fuente de luz independiente, monitorea continuamente la condición de las fuentes de luz para garantizar que la fuente de luz sea confiable.
- Múltiples modos de medición: modo de gestión de calidad, modo de muestra; Cumple con los requisitos de más usuarios.
- Múltiples accesorios, portamuestras, abrazadera de fijación, adecuados para más condiciones de trabajo
- Almacenamiento de datos de gran capacidad, para resultados de prueba de 20000 piezas.
- Localización de cámara incorporada.
- Funciones ampliadas más potentes en el software para PC.
Industria de Aplicaciones
El espectrofotómetro de sobremesa YR05474 se utiliza para realizar análisis y transmisiones de color precisos en laboratorios. Se puede aplicar ampliamente en diferentes industrias, como plásticos, electrónica, pintura y tinta, imprenta, prendas de vestir, cuero, papel, automotriz, médica, cosmética, alimentos, institutos de ciencia, laboratorios.
Especificación Técnica
| Model | YR05474 (current) |
| optical geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
| Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze (ASTM D1003) | |
| Complies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
| Integrating sphere size | Φ 154 mm |
| Light source device | Xenon lamp 360nm-780nm, 400nm cut-off xenon lamp, 420nm cut-off xenon lamp, 460nm cut-off xenon lamp |
| Spectrophotometric mode | concave grating |
| Sensor | 256-element dual array CMOS image sensor |
| Wavelength range | 360-780nm |
| Wavelength step | 10nm |
| Half-bandwidth | 5nm |
| Reflectance range | 0~200% |
| Measurement aperture | Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive: Φ30mm/Φ25mm; Observation: 1. Automatic identification of switch gauge 2. Custom gauge configuration and lens position | |
| Specular component | Reflectance: SCI&SCE |
| Transmittance: SCI&SCE | |
| Color space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
| Color difference formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
| Colorimetric index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
| YI (ASTM D1925, ASTM 313), | |
| MI (metamerism index), | |
| Staining fastness, color fastness, color intensity, opacity, | |
| Gardner Index, Pt-Co Index, Index 555, Haze (ASTM D1003) | |
| Observer angle | 2° and 10° |
| illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
| Displayed data | Spectrogram/values, chromaticity values, color difference values/chart, pass/fail result, color compensation |
| Measuring time | About 2.4 s (SCI and SCE measurement about 5 s) |
| Repeatability | Spectral reflectance: Φ25.4 mm/SCI, standard deviation within 0.06 % (400 nm to 700 nm: within 0.05 %) |
| Chromaticity value: Φ25.4 mm/SCI, standard deviation within ΔE*ab 0.012 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) | |
| Spectral transmittance: Φ25.4 mm/SCI, standard deviation within 0.06 % (400 nm to 700 nm: within 0.06 %) | |
| Chromaticity value: Φ25.4 mm/SCI, standard deviation within ΔE*ab 0.015 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) | |
| Error between instruments | Φ25.4 mm/SCI, within ΔE*ab 0.12 |
| (Average of 12 BCRA Series II color tiles) | |
| Size | 370×300×200mm |
| Weight | About 9.6 kg |
| Power supply | 24 V DC, 3 A power adapter |
| Light source device lifespan | 5 years, over 3 million measurements. |
| Monitor | 7″ capacitive TFT touchscreen |
| Data port | USB serial port, Bluetooth and printing |
| Data storage | Standard 5000 pieces, sample 40000 pieces |
| Language | Simplified Chinese, Traditional Chinese, English (German, French, and Spanish optional custom) |
| Working environment | Temperature: 0~40℃; Humidity: 0~85% (non-condensing) |
| Storage environment | Temperature: -20~50℃; Humidity: 0~85% (non-condensing) |
| Standard accessory | Power adapter, user guide, CD disk (PC software), USB cable, standard calibration plate, black calibration cavity, black transmission deflector, sample holder, gauge 25.4, gauge 15, gauge 8, gauge 4, transmissive test component |
| Optional accessory | Micro printer, micro-aperture transmission test clamp component (4 mm), instrument inversion components |
| Notes: Specifications are subject to change without notice. | |
Products related to model YR05474

YR06702//YR06702-3 Series Single and Dual Beam UV-Visible Spectrophotometer
Ver producto
Array Spectrophotometer YR06664
Ver producto
Non-contact Benchtop Spectrophotometer YR05480
Ver producto
Biophotometer Micro Spectrophotometer YR06033
Ver producto
Spectrophotometer double beam YR01862-1 - YR01862-2
Ver producto
Micro-Spectrophotometer YR06035
Ver producto
Micro-Spectrophotometer YR06034
Ver producto
Micro-Spectrophotometer YR06033-1
Ver productoFrequently Asked Questions about the Spectrophotometer YR05474
Is the YR05474 suitable for both translucent and opaque samples?
Yes, this spectrophotometer is designed to handle both translucent and opaque materials seamlessly, accommodating various substances including transparent liquids.
How much data can the YR05474 store?
The YR05474 can store up to 40,000 records, enabling comprehensive data tracking across extensive testing phases.
Does it allow for adjustable measurement apertures?
Yes, with three distinct adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), this device adapts to different sample sizes effectively.
How do I choose the right Spectrophotometer YR05474 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.