Spectrophotometer YR05475

Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 is an advanced tool crafted by Kalstein for precise color analysis in varied laboratory settings. This spectrophotometer leverages a pulsed xenon lamp that guarantees both longevity and consistent performance during tests. Its 7-inch TFT touchscreen facilitates user interaction, while its optical geometry accommodates both reflective and transmissive measurements. The dual-array CMOS sensor and automatic aperture system promise accurate readings across different sample types, bolstered by its robust data storage capacity and enhanced software for comprehensive result tracking. Choose the YR05475 for superior R&D quality control in plastics, paint, food, cosmetics, and medicine sectors.
This page provides an overview of the Table top spectrophotometer with pulsed xenon lamp YR05475, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in United States, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Table top spectrophotometer with pulsed xenon lamp YR05475, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
This spectrophotometer excels in quality control and product development laboratories across automotive, cosmetics, medical, and food industries. By measuring reflectance and transmittance on broad material types, the YR05475 enhances quality verification processes, upholding high standards throughout production stages.
For the market in United States, evaluation should consider local context such as FDA regulation, large hospital networks, biotech hubs and match the product to the real workload of the laboratory.
Market price range

The YR05475 spectrophotometer is competitively priced and offers exceptional value, with products in this category typically ranging from approximately $10,400 to $11,200 USD. Its cost-effectiveness makes it an attractive investment for businesses aiming for precision in color analysis without compromising on quality. To explore tailored pricing for your specific industry needs, consider requesting a personalized quote effortlessly through the Kalstein Plus platform, which grants you bespoke pricing information at your convenience.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In United States, budget comparison should include FDA references, 120V/60Hz power conditions, accessories, logistics and after-sales support.
Value for money

The YR05475 boasts numerous advantages, such as a temperature compensation system ensuring measurement accuracy under diverse environmental conditions. It offers comprehensive lighting options and an ergonomic design for user-friendly, prolonged usage. However, the device may necessitate regular calibrations under intensive use to sustain optimal accuracy.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

This spectrophotometer excels in quality control and product development laboratories across automotive, cosmetics, medical, and food industries. By measuring reflectance and transmittance on broad material types, the YR05475 enhances quality verification processes, upholding high standards throughout production stages.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

To prolong the functionality of the YR05475, periodic calibrations and maintaining the device within a stable environment are advised. Aligning the measurement aperture with sample types and specific testing scenarios will lead to superior accuracy. Now is the time to leverage the Kalstein Plus platform for a custom quote to see how the YR05475 can optimize your quality control processes with precision and reliability.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to United States helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Spectrophotometer YR05475

Spectrophotometer YR05475
Características
- Alta configuración de hardware: pantalla táctil capacitiva a color TFT de 7 pulgadas; Bluetooth 2.1; Rejilla cóncava.
- Sensor CMOS de doble matriz de 256 elementos de imagen; Lámpara de xenón estable de larga vida útil.
- Con espectro reflectante y transmisivo, valor de laboratorio preciso, bueno para calcular la fórmula de color y hacer una transmisión de color precisa.
- Apertura de medición de identificación automática. Libremente conmutable entre 3 aperturas de medición: Φ 25,4 mm/8 mm/4 mm. Los usuarios también pueden personalizar las aperturas.
- Sensor de temperatura incorporado para monitorear y compensar la temperatura de medición para garantizar una medición más precisa.
- Rango de longitud de onda 360nm - 780nm. Corte integrado de 400 nm, más profesional en la medición UV.
- Detector de fuente de luz independiente, monitorea continuamente la condición de las fuentes de luz para garantizar que la fuente de luz sea confiable.
- Múltiples modos de medición: modo de gestión de calidad, modo de muestra; Cumplir con los requisitos de más usuarios
- Múltiples accesorios, portamuestras, abrazadera de fijación, adecuados para más condiciones de trabajo.
- Almacenamiento de datos de gran capacidad, para resultados de prueba de 20000 piezas.
- Localización de cámara incorporada.
- Funciones ampliadas más potentes en el software para PC.
Industria de aplicaciones
El espectrofotómetro de sobremesa YR05475 se utiliza para realizar análisis y transmisiones de color precisos en laboratorios. Se puede aplicar ampliamente en diferentes industrias, como plásticos, electrónica, pintura y tinta, imprenta, prendas de vestir, cuero, papel, automotriz, médica, cosmética, alimentos, institutos de ciencia, laboratorios.
Especificación técnica
| Model | YR05475 (current)(pulsed xenon lamp) |
| optical geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
| Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze (ASTM D1003) | |
| Complies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
| Integrating sphere size | Φ 154 mm |
| Light source device | Xenon lamp 360nm-780nm, xenon lamp cut-off at 400nm |
| Spectrophotometric mode | concave grating |
| Sensor | 256-element dual-array CMOS image sensor |
| Wavelength range | 360-780nm |
| Wavelength step | 10nm |
| Half-bandwidth | 5nm |
| Reflectance range | 0~200% |
| Measurement aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive: Φ30mm/Φ25.4mm; Observation: 1. Automatic identification of switch gauge 2. Custom gauge setting and lens position | |
| Specular component | Reflectance: SCI&SCE |
| Transmittance: SCI&SCE | |
| Color space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
| Color difference formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
| Colorimetric index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (metamerism index), staining fastness, color fastness, color intensity, opacity, Gardner index, Pt-Co index, index 555, Haze (ASTM D1003) |
| Observer angle | 2° and 10° |
| Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
| Displayed data | Spectrogram/values, chromaticity values, color difference values/chart, pass/fail result, color compensation |
| Measuring time | About 2.4 s (SCI and SCE measurement about 5 s) |
| Repeatability | Spectral reflectance: Φ25.4 mm/SCI, standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
| Chromaticity value: Φ25.4 mm/SCI, standard deviation within ΔE*ab 0.015 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) | |
| Spectral transmittance: Φ25.4 mm/SCI, standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
| Chromaticity value: Φ25.4 mm/SCI, standard deviation within ΔE*ab 0.018 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration) | |
| Error between instruments | Φ25.4 mm/SCI, within ΔE*ab 0.15 |
| (Average of 12 BCRA Series II color tiles) | |
| Size | 370×300×200mm |
| Weight | About 9.6 kg |
| Power supply | 24 V DC power adapter, 3 A |
| Light source device lifespan | 5 years, over 3 million measurements. |
| Monitor | 7″ capacitive TFT touchscreen |
| Data port | USB serial port and printing |
| Data storage | Standard 2000 pieces, sample 20000 pieces |
| Language | simplified Chinese, traditional Chinese, English, |
| Working environment | Temperature: 0~40℃; Humidity: 0~85% (non-condensing) |
| Storage environment | Temperature: -20~50℃; Humidity: 0~85% (non-condensing) |
| Standard accessory | Power adapter, user guide, CD disk (PC software), USB cable, standard calibration plate, black calibration cavity, black transmission deflector, sample holder, gauge 25.4, gauge 8, gauge 4, |
| Optional accessory | Micro printer, transmissive test clamp component, micro-aperture transmission test clamp component (4 mm), instrument inversion components |
| Notes: Specifications are subject to change without prior notice. | |
Products related to model YR05475

YR06702//YR06702-3 Series Single and Dual Beam UV-Visible Spectrophotometer
Ver producto
Array Spectrophotometer YR06664
Ver producto
Non-contact Benchtop Spectrophotometer YR05480
Ver producto
Biophotometer Micro Spectrophotometer YR06033
Ver producto
Spectrophotometer double beam YR01862-1 - YR01862-2
Ver producto
Micro-Spectrophotometer YR06035
Ver producto
Micro-Spectrophotometer YR06034
Ver producto
Micro-Spectrophotometer YR06033-1
Ver productoFrequently Asked Questions about the Spectrophotometer YR05475
Is the YR05475 suitable for both translucent and opaque samples?
Yes, it is equipped to accurately analyze a wide range of materials, including liquids, solids, and translucent samples.
What is the data storage capacity of the YR05475?
The model allows storage of up to 20,000 results, supporting extensive data management and analysis.
Can the measurement aperture be adjusted?
Indeed, with three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), the device provides flexibility for various testing conditions.
How do I choose the right Spectrophotometer YR05475 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.