Biological Safety Cabinet YR06538: A Comprehensive Guide
Product Description
The Biological Safety Cabinet YR06538 is a state-of-the-art solution designed to protect personnel, products, and the environment. It operates on a negative pressure system that prevents leaks, ensuring maximum safety in laboratory settings. The cabinet utilizes a 70% internal circulation and 30% external exhaust principle, facilitating effective air management.
The structure is crafted from high-quality cold-rolled steel, showcasing a work surface made of corrosion-resistant physical-chemical plates. The precision laser cutting and electrostatic epoxy resin surface treatment guarantee durability and longevity. An intelligent control system featuring an LCD touch panel enhances user experience by providing an intuitive understanding of operational status, while compliance with international standards ISO14644.1 Class 5 (equivalent to US Federal 209E Class 100) affirms its quality.
Powered by a German EBM motor known for its high airflow and low energy consumption, the unit is optimized to minimize turbulence and ensure uniform airflow. It is equipped with external high-efficiency HEPA filters and ultra-high-efficiency ULPA filters, contributing to superior filtration capabilities.
Market Price
The YR06538 model is competitively priced at approximately $1235.00, making it an accessible choice for laboratories requiring high levels of biological safety. Below is a comparison table showcasing key specifications and features of the YR06538 model and its closest variant, YR06542, for better understanding.
| Specifications | YR06538 | YR06542 |
|---|---|---|
| Model | YR06538 | YR06542 |
| External Size (mm) | 900 x 760 x 2250 | 1800 x 760 x 2250 |
| Internal Size (mm) | 740 x 600 x 600 | 1640 x 600 x 600 |
| Filtration Type | HEPA + ULPA | HEPA + ULPA |
| Weight (kg) | 138 - 198 | 138 - 198 |
| Noise Level (dB) | Less than 60 | Less than 60 |
Frequently Asked Questions
What is the difference between ULPA and HEPA filters?
The ULPA filter series has an ultra-high efficiency rating of 99.999%, whereas HEPA filters have a high efficiency rating of 99.995%. Both types are excellent, but ULPA filters provide a slightly higher level of purity.
What is the accuracy of the downward airflow control?
The downward airflow control accuracy is set at 0.015 m/s, ensuring uniformity and stability of airflow to maintain sterility within the work area.
What sizes are available?
The YR06538 model is available in dimensions suited for various laboratory setups, specifically designed to fit into standard laboratory spaces while ensuring optimal functionality.
What level of cleanliness does the cabinet guarantee?
The cabinet guarantees Level 5 cleanliness according to the international standard ISO14644.1, equivalent to US Federal 209E Class 100, which is a strict requirement for sensitive environments.
What are the advantages of the YR06538 model?
The YR06538 model advantages include double filtration with HEPA and ULPA filters, superior negative pressure design preventing leaks, optimized airflow for uniformity, and a robust construction from cold-rolled steel.
What are the environmental requirements for the cabinet?
The operational environment should be maintained within a temperature range of 10-30°C and relative humidity below 70% to ensure optimal performance.
Can I request a quote for this product?
Yes, you can request a quote for the YR06538 Biological Safety Cabinet through our inquiry channels. We are here to assist you with your laboratory needs.
Pros and Cons
Pros:
- Double Filtration: Utilizes external HEPA filters and ULPA/HEPA downward flow filters, ensuring up to 99.999% efficiency.
- Superior Safety (Negative Pressure): The design effectively prevents leaks, protecting the operator and the environment.
- Optimized Design: A well-designed airflow duct and optimized negative pressure box for airflow uniformity.
- High-Performance German Motor: Employs an EBM motor that is energy-efficient with a high air volume.
- Durable Construction: Features corrosion-resistant cold-rolled steel with epoxy resin surface treatment.
Cons:
- Environmental Requirements: The work environment must be maintained between 10-30°C and relative humidity below 70%.
- Shipping Weight: The shipping weight is considerable, ranging from 138 kg to 198 kg, which may complicate transport and installation.
- Flow Limitations: While recirculating 70% internally, the 30% external discharge necessitates consideration of an exhaust ventilation system.
Field Usage
The Class II Type A2 Biological Safety Cabinet is essential for handling biological agents of low to moderate risk, such as viruses, bacteria, and cell cultures that require biosafety. It is the standard choice in microbiology laboratories, hospitals, and biotechnology and pharmaceutical research centers where protecting products, personnel, and the environment is critical. Its vibration control capability (semi-peak: 3μm) and stable airflow are vital for sensitive experiments.
Recommendations
To ensure longevity and maximum safety:
- Conduct regular maintenance on the filters and check the calibration of the imported sensor.
- Ensure the work environment meets temperature (10-30°C) and humidity (below 70%) requirements.
- Periodically check the inlet airflow speed (average 0.53m/s to 0.56m/s) and the downward airflow speed (average 0.35m/s) to ensure that negative pressure protection remains effective.
- Utilize high-capacity mobile wheels for initial positioning and ensure stability before operation.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.