Interpreting Results and Reading Measurements with the YR06055 Orbital Shaker

Explore how to accurately interpret results and read measurements from the YR06055 Orbital Shaker, focusing on operational principles, display readings, and com

3D available

Interpreting Results and Reading Measurements with the YR06055 Orbital Shaker

The YR06055 Orbital Shaker is a versatile laboratory instrument designed for sample homogenization and mixing in various scientific fields. Understanding how to interpret results and read measurements from this equipment is crucial for achieving reproducible and accurate experimental outcomes. This article will explore the operational principles, display readings, common misinterpretations, and provide practical tips for users of the YR06055.

Understanding the Operational Principles of the YR06055

The YR06055 operates on the principle of orbital shaking, where samples are agitated in a circular motion, allowing for effective mixing. The shaker's speed can be adjusted between 40 to 200 rpm, which is essential for different sample types and volumes.

The brushless motor ensures a stable and quiet operation, minimizing vibrations that could affect the accuracy of measurements. It is important for users to understand how different speed settings can impact the mixing efficiency and homogeneity of samples, especially when working with sensitive biological materials.

Display Reading and Measurement Interpretation

The YR06055 features an LED display that shows real-time information about the operational settings, including speed and time duration. Understanding how to read this display is vital for ensuring proper usage. The speed is displayed in revolutions per minute (rpm), while the time can be set from 1 minute to 23 hours and 59 minutes.

To interpret the results correctly, users should ensure that the selected speed aligns with the specific requirements of their samples. For example, lower speeds may be more suitable for delicate samples, while higher speeds can be used for more robust materials.

Common Misinterpretations in Results

One common misinterpretation relates to the speed settings displayed. Users may mistakenly believe that a higher rpm always equates to better results. However, the appropriate speed varies with the sample type. For instance, cell suspensions may require gentle mixing to avoid shear stress, while viscous solutions might need higher speeds.

Additionally, misunderstanding the timing can lead to over-mixing or under-mixing, affecting the consistency and reliability of experimental results. Monitoring the display closely during operation is essential.

Practical Tips for Reading Measurements Correctly

  • Always calibrate the shaker before use by running a test with a known sample.
  • Familiarize yourself with the speed and time settings specific to your application.
  • Keep a log of speed and time settings used during experiments to identify optimal conditions based on previous results.
  • Conduct multiple trials with variations in speed and time to evaluate the effects on your results.

Technical Specifications of the YR06055

SpecificationDetails
ModelYR06055
Motor TypeBrushless motor
Plate Size250 x 250 mm
Max Load2 kg
Speed Range40 - 200 rpm
Timing Range1 min - 23h 59 min
DisplayLED display
Power30W
Voltage100-240V, 50/60Hz
Size260 x 355 x 135 mm

Frequently Asked Questions

What are the best practices for setting the speed on the YR06055?

Determining the optimal speed setting for the YR06055 should be based on the nature of your samples. For fragile materials, a lower speed is recommended, while more resilient substances can tolerate higher speeds. Always test different settings to find what works best for your specific applications.

How do I troubleshoot if the display shows incorrect readings?

If the display shows incorrect readings, first check the power connection and ensure the shaker is properly set up. If issues persist, reset the unit and re-check your settings. Consult the user manual for further diagnostic steps.

What types of samples can I use with the YR06055 Orbital Shaker?

The YR06055 is suitable for a variety of samples, including biological cells, chemical solutions, and viscous materials. Always ensure that your sample does not exceed the maximum load of 2 kg to prevent damage to the shaker.

Can I use the YR06055 for extended periods of time?

Yes, the YR06055 is designed for continuous operation for up to 23 hours and 59 minutes. However, it is recommended to monitor the unit during long runs to ensure optimal performance and avoid overheating.

What maintenance does the YR06055 require?

The YR06055 requires minimal maintenance due to its brushless motor design. Regularly check for cleanliness and ensure that no liquid spills onto the unit. Calibration should be performed periodically to ensure accuracy.

Is there a warranty for the YR06055 Orbital Shaker?

Yes, the YR06055 comes with a warranty that typically covers manufacturing defects. It's important to review the warranty terms upon purchase for specific details regarding coverage and service intervals.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Orbital Shaker YR06055 with all specifications, dimensions, accessories and quote options.
View product datasheet →