Description
‘-86℃ Digital display Ultra low temperature upright freezer for Lab/Hospital 588L
ULT freezer is specially designed and manufactured for long term storage of various biological products, including viruses, germs, erythrocytes, leucocytes and cutis. Applications can be found in blood banks, hospitals, biological engineering institutes and marine fishery companies.
Features
- Microprocessor-controlled system designed for controlled rage of -40ºC to -86ºC for cabinet space with 1ºC increment.
- Settable high temperature and low temperature alarms.
- Automatic clean-filter alarm and sensor error alert.
- Adjustable storage shelf height.
- Optional temperature recorder. storage racks and storage box
- Installation and Application
- Wide rage operating voltage system from 187V to 242V designed to allow units installed in areas with poor voltage condition.
- Suitable for 10ºC to 32ºCambient temperature
Reliability
- Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber.
- Specialized control system design for a well-balanced operation of cascade refrigeration system.
- Positive filed proven reliability record.
Safety
- Malfunction alarms including high and low temperature, power failure, sensor error, clean-filter, and extremely high ambient.
- Capable of producing two types of alarm outputs: audible buzzer and visible flashing light.
- Door open feature standard and USB port for temperature date downloading standard on upright models.
- Remote alarm contacts.
Energy saving
- Unique door seal design for the minimum loss of cold temperature during a door opening.
- High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability.
Model | YR05109 | |
Specificaitons
|
Shelf/drawer QTY | Stainless steel shelf/3 |
Cooling | Direct cooling | |
Defrost | Manual | |
Refrigerant | Mixed-gas | |
Power Consumption(kWh/24h) | 16.5 | |
Noise(db) | 53 | |
Ambient temperature(℃) | 10~32℃ | |
Temperature range(℃) | -40~-86℃ | |
Cooling system
|
Compressor brand/QTY | SECOP/2 |
Sensor | PTC | |
Temperature controller | Microprocessor | |
Display | Digital display | |
Power
|
Voltage/frequency(V/Hz) | 220/50Hz |
Power(W) | 1500W | |
Current(A) | 9.1A | |
Material
|
Inside material | Stainless steel |
Outside material | Color sprayed steel | |
Insulation | PURF | |
Size
|
Capacity(L/cu.ft) | 588/20.76 |
NT./GT.(kg) | 290/360 | |
Exterior size(W*D*H)(mm) | 880*1090*1995 | |
Interior size(W*D*H)(mm) | 606*738*1310 | |
Package size(W*D*H)(mm) | 970*1140*2190 | |
CBM | 2.42 | |
20GP/40GP/40HQ | 12/24/24 | |
Frozen Racks
|
Racks | 16(5X5) |
Boxes (2 Inches) | 400 | |
Samples(2ml) | 40000 | |
Alarm
|
High/low temperature | Y |
Power failure | Y | |
Abnormal voltage | Y | |
Sensor error | Y | |
Filter screen check | Y | |
Thermostat failure | Y | |
Low battery | Y | |
Condenser clean | Y | |
High ambient temperature | Y | |
Door ajar | Y | |
Power failure backup system(alarm) | 72h | |
Accessories
|
Castor | Y |
Inside door | 2 | |
Test hole QTY/diameter | 1/25MM | |
USB port | Y | |
Chart recorder | / | |
Data logger | Optional | |
Remote alarm port | Y | |
Optional
|
CO2 back up system | Optional |
LN2 back up system | Optional | |
Other | Certification | ISO.CE |