Description
The Patient Monitor YR02176 is an advanced and versatile monitoring device designed to meet the demands of critical healthcare environments, including Operating Theaters (OT) and Intensive Care Units (ICU). This state-of-the-art monitor boasts a 15-inch LCD screen and modular parameter configuration, ensuring comprehensive and customizable patient data. It comes equipped with standard monitoring capabilities such as ECG, SPO2, TEMP, NIBP, RESP, and PR/HR, with options for enhanced features like Masimo/Nellcor SpO2, Dual-IBP, and EtCO2. This device’s flexibility makes it a vital tool tailored to diverse medical requirements, ensuring optimal patient safety.
Market Price
In today’s competitive healthcare technology landscape, understanding the financial investment for patient monitoring solutions is essential. Patient monitors like the YR02176 typically range between $4,276 and $5,000 USD, reflecting their sophisticated technology and reliable features. If you are interested in obtaining a precise quotation, please request a detailed quote via the Kalstein Plus platform.
Frequently Asked Questions
Which facilities can benefit from the Patient Monitor YR02176?
This monitor is highly suitable for use in high-dependency units, operating theaters, and intensive care units where continuous patient monitoring is imperative.
Is the device portable?
Yes, the YR02176 includes flexible mounting options, such as a trolley or wall mount, making it adaptable for various settings within a hospital.
Advantages and Disadvantages
The primary advantage of the YR02176 lies in its modular design, enabling healthcare providers to customize the device to address specific clinical requirements. It ensures reliable accuracy in vital sign monitoring, essential for patient safety. However, some users may find the initial setup complex due to its advanced features. Training is recommended to fully leverage its capabilities.
Field Application
The Patient Monitor YR02176 is instrumental in critical care settings, offering continuous information on patient vital signs. This real-time data allows medical teams to make informed decisions quickly, significantly enhancing the quality of patient care. Its robust construction and extensive feature set make it indispensable in high-stakes scenarios.
Recommendations
To maximize the efficiency and accuracy of the YR02176, regular maintenance and calibration are advisable. Given its extensive customization options, initial staff training is beneficial to enhance its daily practical utility. Always consult the manual for detailed configuration guidance. For more information and to request a quote, visit the Kalstein Plus platform.
Features
- 15-inch LCD screen
- Modular parameter configuration
- Standard monitoring: ECG, SPO2, TEMP, NIBP, RESP, PR/HR
- Options for advanced monitoring capabilities
- Flexible mounting options
- High-resolution displays
Technical Specifications
Model | YR02176 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 20~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |