Description
The Grating Spectrophotometer YR05493 is an innovative tool designed for precise color measurement across a wide range of industries. This advanced device is perfect for applications in electronics, plastics, textiles, automotive, cosmetics, and food. It includes three measurement apertures for added versatility and a 1000-line grating technology, enabling stable and accurate color measurements within the visible spectrum of 400 to 700 nm. Its ergonomic design, along with a dual d/8 optical structure, allows for both SCI and SCE measurements and complies with international standards like CIE No.15 and ASTM E1164.
Market Price
The YR05493 is positioned in the market with a price range between approximately $9,000 and $9,800 USD depending on the selected configurations and accessories. This spectrophotometer represents a strategic investment for companies seeking enhanced precision in their color management processes. To obtain a personalized quote or generate an automatic quote, visit the Kalstein Plus platform for a quick and reliable purchasing experience.
Frequently Asked Questions
- What applications is the YR05493 recommended for?
It is highly recommended for color quality control in industries such as plastics, textiles, ceramics, and printing. It’s also particularly effective for fluorescent samples. - Is it PC-compatible?
Yes, the YR05493 comes with PC-compatible color management software for detailed analysis and comprehensive color quality data management. - What is the storage capacity?
The device can store up to 1,000 standards and 30,000 samples, providing superb storage options for detailed, organized record-keeping.
Advantages and Disadvantages
The YR05493 offers numerous advantages, such as exceptional precision with a standard deviation ΔE*ab of only 0.03, adaptability through varied apertures, and compatibility with various color spaces and light sources. Its connectivity options include fast data transfers through USB and Bluetooth 4.2. However, it is limited to the visible spectrum (400-700 nm), so it might not be suitable for applications that require broader wavelength measurements.
Field Applications
The YR05493 is largely used in industries that demand high color accuracy, including plastics manufacturing, textiles, coatings, and ceramics. Its dual measurement modes (SCI and SCE), alongside different apertures, enable it to adapt efficiently to varied sample sizes, ensuring consistent results throughout. It’s also utilized for color verification in signage and reflective films, underscoring its value as an essential tool in laboratory and production settings.
Recommendations
To optimize the performance of your YR05493, regular calibration is critical, and the device should be housed in a clean, dust-free environment. Its lithium-ion battery supports up to 6,000 measurements over eight hours, so periodic recharging is recommended. For a customized quote or to generate a quick one, harness the capabilities of Kalstein Plus and discover how the YR05493 Grating Spectrophotometer can refine your industry’s color control procedures, boosting precision and efficiency throughout your production processes.
Technical Specifications
Model | YR05493 |
Optical Geometry | D/8 (diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded); Include UV / excluded UV light source | |
Conforms to CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Characteristic | 3 measuring apertures for accurate color analysis and transmission in laboratory |
Used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics, and for fluorescent sample measurement. | |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | 3 apertures: MAV:Φ8mm/Φ10mm; SAV:Φ4mm/Φ5mm; LAV:1x3mm |
LAV1x3mm: Slightly poor accuracy, can be used for color test | |
Specular Component | SCI & SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99, Munsell(C/2) |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, DINΔE99, ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313, CIE/ISO, AATCC, Hunter) |
YI(ASTM D1925, ASTM 313) | |
Metamerism Index MI | |
Staining Fastness, Color Fastness, Color Strength, Opacity | |
8° Glossiness, 555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.03 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating, stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | Approx 600g |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 4.2 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | Simplified Chinese, English, traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture, 1x3mm tip aperture |
Optional Accessory | Micro Printer, Powder Test Box, Holding base |
Notes | The specifications are subject to change without notice. |