Description
pH Mode:
- Professional portable pH meter is equipped with a backlit LCD display.
- 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
- Automatic electrode diagnosis shows the pH slope and offset.
- Automatic temperature compensation ensures accurate readings over the entire range.
- Calibration due alarm prompts user to calibrate the meter regularly.
ORP Mode:
- 1 point offset calibration allows adjusting the displayed value to a known standard.
- Relative and absolute millivolt modes ensure the reliable ORP measurements.
Other Features:
- Auto-Read function senses and locks the measurement endpoint.
- Auto-Power Off effectively conserves battery life.
- Setup menu allows setting the pH buffer group, number of calibration points, resolution, stability criteria, date and time, etc.
- Reset function automatically resumes all settings back to the factory defaults.
- Expanded memory stores or recalls up to 500 data sets.
- USB communication interface is easy to transfer data to PC.
- Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the meter smoothly.
Technical Specification:
Model | YR0220A | YR0210A | |
pH
|
Range | -2.00~20.00pH | -2.000~20.000pH |
Resolution | 0.01pH | 0.001, 0.01, 0.1pH, selectable | |
Accuracy | ±0.01pH | ±0.002pH | |
Calibration Points | 1 to 3 points | 1 to 5 points | |
pH Buffer Options | USA (4.01/7.00/10.01), NIST (4.01/6.86/9.18) | USA, NIST, DIN, 2 custom buffers | |
ORP
|
mV Range | ±1999mV | ±1999.9mV |
Relative mV Range | — | ±1999.9mV | |
Resolution | 1mV | 0.1, 1mV, selectable | |
Accuracy | ±1mV | ±0.2mV | |
Calibration Points | — | 1 point | |
Temperature
|
Range | 0~105°C/32~221°F | 0~105°C/32~221°F |
Resolution | 0.1°C/0.1°F | 0.1°C/0.1°F | |
Accuracy | ±0.5°C/±0.9°F | ±0.5°C/±0.9°F | |
Offset Calibration | 1 point, reading ±10°C | 1 point, reading ±10°C | |
Other Specification
|
Temperature Compensation | 0~100°C, manual or automatic | 0~100°C, manual or automatic |
Stability Criteria | — | Low or high | |
Calibration Due Alarm | — | 1 to 31 days or off | |
Slope/Offset Display | Yes | ||
Hold Function | Manual or auto-endpoint | ||
Auto-Off | 30 minutes after last key pressed |
10, 20 or 30 minutes after last key pressed
|
|
Memory | 100 data sets | 500 data sets | |
Communication Interface | USB | ||
Connector | BNC, 3.5mm jack socket | ||
Display | Custom LCD (80×60mm) | ||
Power Requirements | 3×1.5V AA batteries or DC5V power adapter | ||
Battery Life | Approximately 150 hours (Turn off the backlight) | ||
Dimensions | 170(L)× 85 (W)×30(H)mm | ||
Weight | 300g |