The Bedside Monitor YR02173 is a highly advanced medical device designed for precise patient monitoring. With its 12.1-inch touch screen and multiple monitoring features, it provides comprehensive support for critical care environments. Included in its array of functions are the 5-lead ECG, COMEN SpO2, and NIBP, among others, enhancing its versatility and making it essential in hospitals and clinics. Built with dual-IBP, BIS, Nellcor/Masimo SpO2 options, this monitor ensures accurate physiological readings. Moreover, its thermal recorder and dual-temp capabilities make it a comprehensive tool for patient assessments.
Market Pricing
The Bedside Monitor YR02173 is well-positioned in the mid-to-high range of the medical equipment market, with prices typically ranging from $2000 to $2800 USD. This reflects its advanced functionality and robust design, offering excellent value for healthcare providers seeking reliability and precision.
Frequently Asked Questions
Is the Bedside Monitor YR02173 compatible with different ECG configurations? Yes, it supports both 5-lead and 3-lead ECG configurations, adapting to various clinical needs.
How portable is the Bedside Monitor YR02173? The monitor can be easily mounted on a trolley or wall, allowing flexible use in different medical settings.
Can the monitor integrate with hospital information systems? Yes, it has the capability to interface with multiple systems for streamlined patient data management.
Pros and Cons
Pros: Offers multiple monitoring parameters, has a user-friendly touch screen, and provides accurate real-time data.
Cons: While highly functional, its comprehensive features might present a learning curve for first-time users.
Product Usage in the Field
In practical scenarios, the Bedside Monitor YR02173 proves indispensable for continuous patient assessment in intensive care units. Its robust design allows healthcare professionals to monitor critical parameters like heart rate and SpO2 levels efficiently. The monitor ensures timely intervention by providing reliable alerts, ensuring patient safety and prompt response to changes in their condition.
Recommendations
For optimal performance, it is recommended to regularly calibrate the device and run routine checks on the ECG leads and SpO2 sensors. Ensuring that software updates are installed promptly will enhance operational efficiency and accuracy.
Features
- 12.1 inch touch screen for easy operation
- Supports 5-lead and 3-lead ECG configurations
- Comprehensive monitoring capabilities including NIBP, SpO2, and temperature
- Dual-IPB, EtCO2, and more advanced monitoring parameters
- Flexible mounting options for bedside or mobile use
Technical Specifications
Model | YR02173 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | 1.25, 2.5, 5.0, 10, 20, 40mm/mV, Auto. | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 15~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 60~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | About 1 Second. | |
Average Time Constant | <10 Second. |