Description
The Automatic Nucleic Acid Extractor YR01869-2 is an advanced tool engineered to enhance the process of nucleic acid extraction, boasting rotary mixing technology for improved output without cross-interference. This cutting-edge device accommodates up to 16 different analyses simultaneously, ensuring efficiency in laboratories with varied assay requirements. Recognized for its innovative design, it features a user-friendly 6.86-inch touch screen and remote operation via smartphone and tablet applications, making it a versatile and indispensable asset for any research lab.
Market Price
The market price for advanced nucleic acid extraction equipment like the Automatic Nucleic Acid Extractor YR01869-2 typically ranges from approximately $8800 to $9680 USD. This makes it a considerable investment for laboratories aiming to boost their operational capabilities with state-of-the-art technology. For those interested in optimizing their purchase, generating a personalized quote through the Kalstein Plus platform can provide exclusive discounts and dedicated technical support tailored to your specific needs.
Frequently Asked Questions
- What types of samples can the Automatic Nucleic Acid Extractor YR01869-2 process? This versatile extractor can handle a wide range of samples, particularly those needed for precise nucleic acid isolation, such as DNA and RNA analyses.
- Is the extractor easy to use? Absolutely. With its intuitive 6.86-inch touchscreen and remote control features, the YR01869-2 facilitates straightforward and efficient operation, allowing for quick experiment setups.
- How do I maintain the extractor in optimal condition? To ensure longevity and performance, regular cleaning and timely software updates are crucial. Additionally, ensure that maintenance is performed by trained personnel to keep the device in peak condition.
Advantages and Disadvantages
Advantages:
- High Flexibility: Capable of managing multiple projects simultaneously, boosting laboratory productivity.
- Automation: Reduces manual intervention with automatic reagent detection and remote updates.
- Safety and Precision: Features such as UV lamps, negative pressure, and HEPA filtration ensure contamination-free results.
- Portability: Compact design makes it easy to deploy across various settings.
Disadvantages:
- Significant Cost: Its high performance comes with a price tag that may be challenging for smaller laboratories.
- Requires Specialized Maintenance: Regular upkeep by knowledgeable staff is necessary to maintain functionality.
Product Use in the Field
The Automatic Nucleic Acid Extractor YR01869-2 is widely used in genetic research labs, clinical diagnostics, and biotechnology applications. Its flexibility is appreciated in diverse settings such as hospitals, forensic laboratories, and scientific institutions, where it facilitates nucleic acid extraction, biological sample analysis, and PCR projects. Its portable design and the ability to operate in various environments make it indispensable for rapidly obtaining results where time and adaptability are crucial.
Recommendations
To maximize the benefits of the Automatic Nucleic Acid Extractor YR01869-2, it is recommended to adhere to manufacturer-provided maintenance protocols, such as regular device cleaning and reagent protocol updates. Furthermore, by running simultaneous tasks, users can make full use of the device’s multitasking capability, thus boosting laboratory efficiency. Utilizing its UV disinfection and HEPA filtration systems helps maintain high accuracy levels by preventing cross-contamination.
Features
- Rotary mixing technology for efficient nucleic acid extraction.
- Multi-platform control with both touchscreen and remote operation.
- Robust safety features including UV and HEPA systems.
- Compatible with various consumables and sample volumes.
- Automated workflow with minimal manual handling.
Technical Specifications
Model | YR01869-2 |
Throughput | 16 |
Processing Volume | 20-1700μL |
Sample Processing Volume | 200-500μL |
Compatible Consumables | Customized 96-deep-well plates, single 6-strip tubes |
Inter-well Difference | CV≤3% |
Mixing Method | Rotary mixing |
Rotary Speed | 100~3000rpm |
Temperature Control Range | Temperature control separately for lysis and elution. |
Temperature range from 30°C to 120°C. | |
Temperature Control Accuracy | Heating speed: 4.0±0.2°C/s. |
Temperature accuracy: ±1.0°C. | |
Temperature uniformity: ≤1.0°C. | |
Languages | Chinese/English |
Protocol Management | Flexible to create, edit and delete protocols |
Operation Mode | Mode 1: Android systems in smartphones/tablets |
Mode 2: 6.86 inch full-color LCD screen | |
Automatic Control | Automatic opening and closing of the experiment cabin |
Reagent Identification | Automatic identification of reagent information and running the assays |
Mixing Sleeve Monitoring | Real-time monitoring of the mixing sleeves status in experiment |
Magnetic Bead Residue | ≤1% |
Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
Disinfection | Ozone + UV disinfection |
Auto Power-off | Auto power-off after UV disinfection |
Negative-Pressure Filtration | Negative pressure HEPA filtration module |
Connection Port Type | USB port |
Weight | 7.4Kg (net) |
Instrument Dimensions | 210mm(L)*229mm(W)*242mm(H) |
Power Supply | AC220V, 50Hz |